2.5
Other Reagents
1. Sodium hydroxide solution: Dissolve 20 g sodium hydroxide
(NaOH) in 5 L deionized (DI) water to prepare 0.1 M NaOH
solution.
2. Calcein-AM staining solution: Prepare Calcein-AM working
solution according to manufacturer’s instructions. Generally,
dilute 2 μL of 1 mM calcein AM stock solution in 1 mL PBS,
vortex the resulting solution to ensure thorough mixing. Keep
from light and use within 24 h.
3
Methods
The process is simply summarized in a flowchart in Fig. 2.
3.1
Setting up 3D
FloTrix® vivaSPIN
Bioreactor on Day 1
1. Calibrate pH sensor (see Note 2).
2. Dismantle all stainless-steel tubes and two 3-blade impellers.
Rinse with ultrapure water thoroughly and sonicate for 60 min.
3. Wash the 5 L culture vessel with mild detergent. Rinse with
ultrapure water thoroughly for three times. Fill up the vessel
with 5 L 0.1 M NaOH solution and soak all stainless-steel tubes
and impellers for 12 h (see Note 3). Discard NaOH solution
safely. Rinse the vessel, tubes, and impellers with ultrapure
water for another three times.
Fig. 2 Flowchart of the protocol, with light blue boxes indicating preparation work involved and dark blue
boxes indicating the cell culture process
116
Huanye Xu et al.